| Home | About Us | Products & Services | Search | Contact Us | |
| THE FOLLOWING LOAD TABLES WERE DEVELOPED IN STRICT CONFORMANCE WITH THE FIBERGLASS LOAD/DEFLECTION CRITERIA . U - UNIFORM IN LBS. PER SQ. FT., C - CONCENTRATED LINE LOAD IN LBS. PER FT. OF WIDTH, DU - UNIFORM LOAD DEFLECTION IN INCHES, DC - CONCENTRATED LINE LOAD DEFLECTION IN INCHES. |
| T-5010 1" DEEP LIGHT DUTY "T" SERIES (LOAD BARS 2" O.C.) | |||||||||||
| CLEAR SPAN (INCHES) |
LOAD
TYPE |
SAFE LOAD 2:1 SAFETY FACTOR | MAXIMUM LOAD | ||||||||
| 12" |
|
4768 .182 2383 .146 |
9532 .364 4766 .291 |
||||||||
| 18" |
|
2144 .401 1608 .321 |
4288 .802 3217 .642 |
||||||||
| 24" |
|
1221 .698 1221 .558 |
2442 1.397 2442 1.117 |
||||||||
| 30" |
|
791 1.070 988 .856 |
1582 2.140 1977 1.712 |
||||||||
| 36" |
|
556 1.152 833 1.209 |
1112 3.024 1667 2.419 |
||||||||
| 42" |
|
413 2.019 723 1.615 |
826 4.038 1446 3.230 |
||||||||
| 48" |
|
320 2.592 640 2.074 |
640 5.184 1280 4.147 |
||||||||